Increasing the accuracy of mass isotopomer analysis through calibration curves constructed using biologically
Tie Shen1, Weiqun Shen, Ying Xiong
1School of Life Science, University of Science and Technology of China, Hefei, Anhui, China. shentie@mail.ustc.edu.cn
Abstract:
Mass isotopomer analysis is an important technique to measure the production and flow of metabolites in living cells, tissues, and organisms. This technique depends on accurate quantifications of different mass isotopomers using mass spectrometry. Constructing calibration curves using standard samples is the most universal approach to convert raw mass spectrometry measurements into quantitative distributions of mass isotopomers. Calibration curve approach has been, however, of very limited use in comprehensive analyses of biological systems, mainly suffering from the lack of extensive range of standard samples with accurately known isotopic enrichment. Here, we present a biological method capable of synthesizing specifically labeled amino acids. These amino acids have well-determined and estimable mass isotopomer distributions and thus can serve as standard samples. In this method, the bacterium strain Methylobacterium salsuginis sp. nov. was cultivated with partially 13C-labeled methanol as the only carbon source to produce 13C-enriched compounds. We show that the mass isotopomer distributions of the various biosynthesized amino acids are well determined and can be reasonably estimated based on proposed binomial approximation if the labeling state of the biomass reached an isotopic steady state. The interference of intramolecular inhomogeneity of 13C isotope abundances caused by biological isotope fractionation was eliminated by estimating average 13C isotope abundance. Further, the predictions are tested experimentally by mass spectrometry (MS) spectra of the labeled glycine, alanine, and aspartic acid. Most of the error in mass spectrometry measurements was less than 0.74 mol% in the test case, significantly reduced as compared with uncalibrated results, and this error is expected to be less than 0.4 mol% in real experiment as revealed by theoretical analysis.
More Related Videos
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
Mass Spectrometry: Isotope Effect
Mass Spectrum: Interpretation
High-Resolution Mass Spectrometry (HRMS)
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Analyzers: Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...