A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016
Photonics-based in vivo total hemoglobin monitoring and clinical relevance
John McMurdy1, Gregory Jay, Selim Suner
1Division of Engineering, Brown University, Providence, RI 02912, USA.
Anemia is a serious disorder which, as a result of antiquated invasive blood testing, is undiagnosed in millions of people in the U.S. As a result of the clinical need, many technological solutions have been proposed to measure total blood hemoglobin, and thus diagnose anemia, noninvasively. Because hemoglobin is the strongest chromophore in tissue, spectroscopic methods have been the most prevalently investigated. Difficulties in extracting a quantitative estimation of hemoglobin based on tissue absorption include variability in the absorption spectra of hemoglobin derivatives, interference from other tissue chromophores, and interpatient physiological variations affecting the effective optical path length of light propagating in tissue. In spite of these challenges, studies with a high degree of correlation between in vitro and in vivo measured total hemoglobin have been disclosed using variants of transmission and diffuse reflection spectroscopy in assorted physiological locations. A review of these technologies and the relevant advantages/disadvantages are presented here.
Anemia is a serious disorder which, as a result of antiquated invasive blood testing, is undiagnosed in millions of people in the U.S. As a result of the clinical need, many technological solutions have been proposed to measure total blood hemoglobin, and thus diagnose anemia, noninvasively. Because hemoglobin is the strongest chromophore in tissue, spectroscopic methods have been the most prevalently investigated. Difficulties in extracting a quantitative estimation of hemoglobin based on tissue absorption include variability in the absorption spectra of hemoglobin derivatives, interference from other tissue chromophores, and interpatient physiological variations affecting the effective optical path length of light propagating in tissue. In spite of these challenges, studies with a high degree of correlation between in vitro and in vivo measured total hemoglobin have been disclosed using variants of transmission and diffuse reflection spectroscopy in assorted physiological locations. A review of these technologies and the relevant advantages/disadvantages are presented here.
More Related Videos
10:35Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
Published on: October 17, 2016
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024