Updated: Jun 23, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
05:54

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla

Published on: October 18, 2021

Subcrestal placement of two-part implants.

Maria Welander1, Ingemar Abrahamsson, Tord Berglundh

  • 1Department of Periodontology, The Sahlgrenska Academy at Göthenburg University, Göthenburg 405 30, Sweden. maria.welander@odontologi.gu.se

Clinical Oral Implants Research
|April 29, 2009
PubMed
Summary

Surface characteristics of dental implants influence bone healing. Modified surfaces on test implants promoted bone growth coronal to the abutment/fixture interface, unlike control implants.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Cost Consequence Analysis of Non-Surgical Treatment Approaches for Patients With Periodontitis.

Journal of clinical periodontology·2026
Same author

Marginal bone loss around implants - What does it mean?

Periodontology 2000·2026
Same author

Association between subclinical coronary artery atherosclerosis and oral health-a study on a Swedish population.

BDJ open·2026
Same author

Peri-Implant Diseases: The Past, the Present, the Future.

Journal of periodontal research·2025
Same author

Association Between Diabetes and Peri-Implantitis: Evidence From a Swedish Register-Based Study.

Journal of clinical periodontology·2025
Same author

Titanium micro-particles are commonly found in soft tissues surrounding dental implants.

Communications medicine·2025

Area of Science:

  • Dental Implantology
  • Biomaterials Science
  • Periodontology

Background:

  • Subcrestal placement of two-part implants is common.
  • Implant surface characteristics can influence osseointegration and bone levels.

Purpose of the Study:

  • To investigate bone healing around two-part implants placed subcrestally.
  • To compare healing with modified versus regular abutment surfaces.

Main Methods:

  • Canine model using mongrel dogs.
  • Subcrestal placement of test (modified surface) and control (regular surface) implants.
  • Histological analysis of biopsies after 4 months.

Main Results:

  • Test implants showed coronal marginal bone levels compared to controls.

More Related Videos

Chronic Implantation of Multiple Flexible Polymer Electrode Arrays
08:54

Chronic Implantation of Multiple Flexible Polymer Electrode Arrays

Published on: October 4, 2019

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
08:15

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects

Published on: August 4, 2020

Related Experiment Videos

Last Updated: Jun 23, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
05:54

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla

Published on: October 18, 2021

Chronic Implantation of Multiple Flexible Polymer Electrode Arrays
08:54

Chronic Implantation of Multiple Flexible Polymer Electrode Arrays

Published on: October 4, 2019

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
08:15

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects

Published on: August 4, 2020

  • 40% of test implants exhibited bone-to-implant contact coronal to the abutment/fixture border.
  • Peri-implant connective tissue at test sites had higher collagen density.
  • Conclusions:

    • Osseointegration coronal to the abutment/fixture interface is possible with two-part implants.
    • Implant component surface characteristics are critical for achieving enhanced bone integration.