Related Experiment Video
Updated: Jun 23, 2026

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Effect of nasal cannula oxygen administration on oxygen concentration at facial and adjacent landmarks
M Orhan-Sungur1, R Komatsu, A Sherman
1Department of Anaesthesiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey.
Abstract:
An oxygen-enriched atmosphere enhances the potential for operating-room fires. We thus determined oxygen concentrations at various facial landmarks during oxygen administration via nasal cannulae. Thirteen supine volunteers were draped similarly to patients undergoing a cervical-node biopsy. Oxygen was delivered in random order through nasal cannulae at rates of 2, 4, and 6 l x min(-1). Oxygen concentration was measured at pre-determined facial landmarks and also distal to the drape at non-facial sites. At a flow of 2 l x min(-1), oxygen concentrations exceeded 23% only within a few centimetres of the nasal cannula. Concentration increased as a function of flow, but rarely exceeded 26%. At all flow rates, concentrations distal to the drape were < 24%. To reduce combustion risk, ignition sources should be kept at least 10 cm from the oxygen outlet when using nasal cannula at a flow rate > or = 4 l x min(-1).
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...

