Distortion product otoacoustic emissions in an industrial setting
George S Korres1, Dimitrios G Balatsouras, Antonis Tzagaroulakis
1Department of Otolaryngology, National University of Athens, Hippokration Hospital, Athens.
Abstract:
Distortion product otoacoustic emissions (DPOAEs) is an objective sensitive test of cochlear function. The aim of this study was the evaluation of noise-induced hearing loss in a group of industrial workers, using this method in conjunction with standard puretone audiometry (PTA). One hundred and five subjects (210 ears) were included in the study. PTA, tympanometry, and DPOAEs were performed. Results were analyzed using a mixed analysis of variance model, and compared with the data of 34 normal persons of similar age and sex. We found statistically significant lower DPOAE levels in the noise-exposed group than in the control group. Additionally, the effect of frequency was significant, indicating that amplitude varied across frequency, with lower responses observed at 4 and 6 kHz, and maximum response found at 2 kHz. PTA showed a statistically significant effect of Group, owed to elevated puretone thresholds in the noise-exposed subjects, but a Frequency main effect was not found, although the interaction between Frequency and Group was statistically significant, as well as the interaction between Frequency and Ear. A main effect for Ear was found only in puretone thresholds, due to better thresholds in the left ears of the subjects, and not in DPOAE measurements. DPOAE levels were selectively affected at the higher frequencies, whereas puretone thresholds were affected at all frequencies. Direct comparison of the number of significantly affected ears between the two methods at 1, 2, and 4 kHz showed statistically significant differences at all comparisons, with more ears affected in PTA in comparison with DPOAEs at 4 kHz, whereas more ears were affected in DPOAEs at the lower frequencies (1 and 2 kHz). Therefore, it may be concluded that DPOAEs and PTA are both sensitive methods in detecting noise-induced hearing loss, with DPOAEs tending to be more sensitive at lower frequencies.
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Beats
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Sound Waves: Interference