Nondipolar content of T wave derived from a myocardial source simulation with increased repolarization inhomogeneity
Milos Kesek1, Ola Gustavsson, Urban Wiklund
1Department of Cardiology, Heart Center, University Hospital, Umeå, Sweden. milos.kesek@comhem.se
Background:
Several conditions with repolarization disturbances are associated with increased level of nondipolar components of the T wave. The nondipolar content has been proposed as a measure of repolarization inhomogeneity. This computer simulation study examines the link between increased nondipolar components and increased repolarization inhomogeneity in an established model.
Methods:
The simulation was performed with Ecgsim software that uses the equivalent double-layer source model. In the model, the shape of transmembrane potential is derived from biological recordings. Increased repolarization inhomogeneity was simulated globally by increasing the variance in action potential duration and locally by introducing changes mimicking acute myocardial infarction. We synthesized surface ECG recordings with 12, 18, and 300 leads. The T-wave residue was calculated by singular value decomposition. The study examined the effects of the number of ECG leads, changes in definition of end of T wave and random noise added to the signal.
Results:
Normal myocardial source gave a low level of nondipolar content. Increased nondipolar content was observed in the two types of increased repolarization inhomogeneity. Noise gave a large increase in the nondipolar content. The sensitivity of the result to noise increased when a higher number of principal components were used in the computation.
Conclusions:
The nondipolar content of the T wave was associated with repolarization inhomogeneity in the computer model. The measure was very sensitive to noise, especially when principal components of high order were included in the computations. Increased number of ECG leads resulted in an increased signal-to-noise ratio.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
12:09Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Published on: January 8, 2013
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrophysiology of Normal Cardiac Rhythm
Bode Plots Construction
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias I: Introduction