Background:
Various materials and methods have been used for augmentation mammaplasty since it was first performed in Japan in the late 1940s. Although augmentation mammaplasty is not associated with an increased risk of breast cancer, a number of studies have reported that breast implants, or subsequent changes around these foreign substances, can affect images made by mammography, CT, or MRI during breast cancer screening. A method that is increasingly being used to detect cancer is positron emission tomography (PET).
Methods:
To determine the effect of augmentation mammaplasty on PET imaging, we subjected ten women who had previously undergone augmentation mammaplasty to PET imaging as well as other imaging methods. We also measured tumor markers and performed pathologic studies.
Results:
The histologic analyses failed to detect any cases of malignancy. We assess the efficacy of PET for detecting breast cancer in women who had undergone augmentation mammaplasty and describe the features of the PET images of these women. Finally, we discuss future research objectives in relation to PET-based screening for breast cancer.
Conclusion:
It is important to identify an imaging methodology that improves the detection of breast cancer in patients with a previous mammaplasty. We show here that FDG-PET may improve breast cancer detection after mammaplasty.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET