Related Experiment Video
Updated: Jun 23, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Lower extremity CT angiography (CTA): initial evaluation of a knowledge-based centerline estimation algorithm for
Justus E Roos1, Tejas Rakshe, David N Tran
1Department of Radiology, Stanford University Medical Center, 300 Pasteur Drive, Room S-072, Stanford, CA 94305-5105, USA. justus.roos@stanford.edu
Rationale And Objectives:
Existing density- and gradient-based automated centerline-extraction algorithms fail in severely diseased or occluded arterial segments for the generation of curved planar reformations (CPRs). We aimed to quantitatively and qualitatively assess the precision of a knowledge-based centerline-extraction algorithm in patients with occluded femoro-popliteal artery (FPA).
Material And Methods:
Computed tomography angiograms of 38 FPA occlusions (mean length 120 mm) were retrospectively identified. Reference centerlines were determined as the mean of eight manual expert readings. Each occlusion was also interpolated using a new knowledge-based algorithm (partial vector space projection [PVSP]), which uses shape information extracted from a separate database of 30 nondiseased FPAs. Precision of PVSP was quantified as the maximum departure error (MDE) from the standard of reference and the proportion of the interpolated centerlines remaining within an assumed vessel radius of 3 mm. Multiple regression method was used to determine the factors predicting the precision of the algorithm. CPR quality was independently assigned by two readers.
Results:
The mean MDE (in mm) for occlusion lengths of <50 mm, 50-100 mm, 100-200 mm, and >200 mm was 0.95, 1.19, 1.40, and 2.25, for manual readings and 1.68, 2.90, 9.43, and 19.95 for PVSP, respectively. MDEs of the algorithm were completely contained within 3 mm of the assumed vessel radius in 20 of 38 occlusions. CPR quality was rated diagnostic by both readers in 23 of 38 occlusions.
Conclusion:
Shape-based centerline extraction of FPA occlusions in lower extremity CTA is feasible, and independent from local density and gradient information. PVSP centerline extraction allows interpolation of occlusions up to 100 mm within the variability of manually derived centerlines.
More Related Videos
06:45Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease III: Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies VII: Vascular Imaging
Pulse Assessment Sites
Imaging Studies for Cardiovascular System V: CT