Related Experiment Video
Updated: Jun 23, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Determination of sample sizes for demonstrating efficacy of radiation countermeasures
Ralph L Kodell1, Shelly Y Lensing, Reid D Landes
1Department of Biostatistics, University of Arkansas for Medical Sciences, Little Rock, Arkansas 72205, USA. rlkodell@uams.edu
Abstract:
In response to the ever increasing threat of radiological and nuclear terrorism, active development of nontoxic new drugs and other countermeasures to protect against and/or mitigate adverse health effects of radiation is ongoing. Although the classical LD(50) study used for many decades as a first step in preclinical toxicity testing of new drugs has been largely replaced by experiments that use fewer animals, the need to evaluate the radioprotective efficacy of new drugs necessitates the conduct of traditional LD(50) comparative studies (FDA, 2002, Federal Register 67, 37988-37998). There is, however, no readily available method to determine the number of animals needed for establishing efficacy in these comparative potency studies. This article presents a sample-size formula based on Student's t for comparative potency testing. It is motivated by the U.S. Food and Drug Administration's (FDA's) requirements for robust efficacy data in the testing of response modifiers in total body irradiation experiments where human studies are not ethical or feasible. Monte Carlo simulation demonstrated the formula's performance for Student's t, Wald, and likelihood ratio tests in both logistic and probit models. Importantly, the results showed clear potential for justifying the use of substantially fewer animals than are customarily used in these studies. The present article may thus initiate a dialogue among researchers who use animals for radioprotection survival studies, institutional animal care and use committees, and drug regulatory bodies to reach a consensus on the number of animals needed to achieve statistically robust results for demonstrating efficacy of radioprotective drugs.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Biological Effects of Radiation
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Dose Size and Dosing Frequency: Determination Methods