Related Experiment Video
Updated: Jun 23, 2026

08:10
Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Hybrid cardiac SPECT/64-slice CTA-derived LV function parameters: correlation and reproducibility assessment
Sobhi Abadi1, Olga R Brook, Shmuel Rispler
1Medical Imaging Department, Toronto General Hospital, Toronto, Ontario M5G2C4, Canada. s_abadi@rambam.health.gov.il
European Journal of Radiology
|May 16, 2009
Summary
This study compared left ventricular (LV) function and volume measurements using SPECT and CT angiography (CTA). While ejection fraction showed good correlation, LV volumes should not be used interchangeably between modalities.
Area of Science:
- Cardiovascular Imaging
- Medical Physics
- Radiology
Background:
- Accurate assessment of left ventricular (LV) function and volumes is crucial in managing coronary artery disease.
- Hybrid SPECT/CT imaging offers a single-session approach for comprehensive cardiac evaluation.
- Evaluating the correlation and reproducibility of parameters derived from different imaging modalities is essential for clinical application.
Purpose of the Study:
- To determine the relationship between SPECT and CT angiography (CTA) measured LV parameters (function and volumes).
- To assess the reproducibility of LV parameters measured using 64-slice CTA.
- To evaluate LV parameters in a single session using a SPECT/CT hybrid device.
Main Methods:
- Seventy-six patients with suspected or known coronary artery disease underwent simultaneous SPECT and 64-slice CTA.
- LV end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were measured using both modalities.
- Intra-observer and inter-observer variability for CTA measurements were calculated.
Main Results:
- A strong correlation was observed between SPECT and CTA for LVEF (r=0.81), ESV (r=0.90), and EDV (r=0.82).
- CTA measurements showed small positive differences for LVEF and more prominent differences for ESV and EDV compared to SPECT.
- Excellent reproducibility was found for all CTA-measured LV parameters, with very low intra- and inter-observer variability.
Conclusions:
- While LVEF measurements from CTA and SPECT correlate well, their interchangeable use requires caution.
- Interchangeable use of LV EDV and ESV measurements between CTA and SPECT should be avoided due to significant differences.
- CTA demonstrates high reproducibility for LV volume and function assessment.