Comparison of 18F-FDG and PiB PET in cognitive impairment
Val J Lowe1, Bradley J Kemp, Clifford R Jack
1Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905, USA. vlowe@mayo.edu
Unlabelled:
The purpose of this study was to compare the diagnostic accuracy of glucose metabolism and amyloid deposition as demonstrated by (18)F-FDG and Pittsburg Compound B (PiB) PET to evaluate subjects with cognitive impairment.
Methods:
Subjects were selected from existing participants in the Mayo Alzheimer's Disease Research Center or Alzheimer's Disease Patient Registry programs. A total of 20 healthy controls and 17 amnestic mild cognitive impairment (aMCI), 6 nonamnestic mild cognitive impairment (naMCI), and 13 Alzheimer disease (AD) subjects were imaged with both PiB and (18)F-FDG PET between March 2006 and August 2007. Global measures for PiB and (18)F-FDG PET uptake, normalized to cerebellum for PiB and pons for (18)F-FDG, were compared. Partial-volume correction, standardized uptake value (SUV), and cortical ratio methods of image analysis were also evaluated in an attempt to optimize the analysis for each test.
Results:
Significant discrimination (P < 0.05) between controls and AD, naMCI and aMCI, naMCI and AD, and aMCI and AD by PiB PET measurements was observed. The paired groupwise comparisons of the global measures demonstrated that PiB PET versus (18)F-FDG PET showed similar significant group separation, with only PiB showing significant separation of naMCI and aMCI subjects.
Conclusion:
PiB PET and (18)F-FDG PET have similar diagnostic accuracy in early cognitive impairment. However, significantly better group discrimination in naMCI and aMCI subjects by PiB, compared with (18)F-FDG, was seen and may suggest early amyloid deposition before cerebral metabolic disruption in this group.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)