Negative pressure pulmonary edema complicating an electrophysiological study
International Journal of Cardiology
|May 19, 2009
Summary
A rare case of acute negative-pressure pulmonary edema occurred during accessory pathway ablation in a patient without structural heart disease. This serious complication is unprecedented in interventional cardiology procedures.
Area of Science:
- Cardiology
- Pulmonary Medicine
- Medical Devices
Background:
- Accessory pathway ablation is a common interventional cardiology procedure.
- Pulmonary edema is a potential complication, but typically cardiogenic.
- Non-cardiogenic negative-pressure pulmonary edema is a rare condition.
Observation:
- A patient undergoing accessory pathway ablation developed acute non-cardiogenic negative-pressure pulmonary edema.
- The patient had no pre-existing structural heart disease.
- The complication occurred during the ablation procedure.
Findings:
- This is the first reported instance of acute non-cardiogenic negative-pressure pulmonary edema during an interventional cardiology procedure.
- The complication was associated with accessory pathway ablation.
Implications:
- Highlights a previously unreported risk associated with accessory pathway ablation.
- Suggests the need for increased awareness and vigilance for this complication in interventional cardiology.
- May inform procedural protocols and patient monitoring during ablation procedures.
Related Concept Videos
Pulmonary Edema II: Pathophysiology
Pulmonary edema is the accumulation of fluid in the interstitial and alveolar spaces of the lungs, impairing gas exchange and oxygen delivery. It may be cardiogenic or noncardiogenic, but both reduce oxygenation and lung compliance.Cardiogenic Pulmonary EdemaCardiogenic edema results from increased hydrostatic pressure in pulmonary capillaries, usually due to left ventricular dysfunction from myocardial infarction, heart failure, or valvular disease. Ineffective cardiac pumping causes blood to...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Diagnosing Pulmonary EmbolismDiagnosing pulmonary embolism (PE) involves clinical assessment and advanced imaging tests. The preferred diagnostic tool is the spiral (helical) CT scan or CT angiography (CTA), which uses intravenous contrast media to visualize the pulmonary vasculature and identify emboli.A ventilation-perfusion (V/Q) scan is an alternative for patients unable to receive contrast media. This scan includes both perfusion and ventilation scanning. Perfusion scanning involves...
Pulmonary Embolism I: Introduction
Pulmonary embolism (PE) occurs when a thrombus, fat or air embolus, amniotic fluid, or tumor tissue blocks one or more pulmonary arteries. These blockages originate in the venous system or the right side of the heart.EtiologyPE primarily arises from deep vein thrombosis (DVT) and other hypercoagulable states, such as inherited thrombophilias. Additional etiological factors include venous stasis, commonly seen in obesity, and endothelial injury from surgery and trauma. Less common causes include...
Cardiac Catheterization II: Right Heart Catheterization
Right Heart Catheterization: An OverviewRight heart catheterization is an invasive diagnostic procedure that measures right-sided cardiac and pulmonary artery pressures, calculates cardiac output, and identifies intracardiac shunts. It provides detailed hemodynamic data essential for diagnosing and managing various cardiovascular conditions, such as pulmonary hypertension.Access SitesCommon access sites for right heart catheterization include the internal jugular vein in the neck region, the...
Measurement of Blood Pressure
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.