Related Experiment Video
Updated: Jun 23, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Time course of carbon monoxide transfer factor after breath-hold diving
R Prediletto1, E Fornai, G Catapano
1CNR Institute of Clinical Physiology, Pisa, Italy.
Abstract:
Breath-hold divers may experience haemoptysis during diving. Central pooling of blood as well as compression of pulmonary gas content can damage the integrity of the blood-gas barrier, resulting in alveolar hemorrhage. The single-breath carbon monoxide test (DL,CO) was used to investigate the blood-gas barrier following diving. The study population consisted of 30 divers recruited from a training course. DL,CO levels were measured before diving and at 2, 10 and 25 min after the last of a series of four dives to depths of 10, 15, 20 and 30 m. When compared to pre-diving values, DL,CO values increased significantly at 2 min following diving in all subjects except one. Thereafter values progressively decreased toward baseline at 10 and 25 min in all subjects but one, while in four divers DL,CO values decreased below baseline. The early but transient increase in DL,CO levels shortly after diving supports the persistence of capillary pooling of red blood cells following emersion. Persistence at 25 min of high DL,CO values in one subject could be attributed by lung CT to extravasation of blood into the alveoli. Early or late DL,CO values >10% below baseline values suggest the presence of pulmonary edema. The relatively high prevalence of DL,CO alterations found suggests caution on the safety of breath-hold diving activities.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...