A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Influence of jet nebulization and oxygen delivery on the fraction of inspired oxygen: an experimental model
Vincent Caille1, Stephan Ehrmann, Eric Boissinot
1INSERM U-618, Université François Rabelais, 37000 Tours, France. vincent.caille@apr.aphp.fr
Background:
The fraction of inspired oxygen (FiO(2)) during oxygen-driven jet nebulization is unknown. In the case of air-driven jet nebulization, oxygen is often added through a nasal device, and again, the FiO(2) is unknown. The aim of this experimental study was to measure FiO(2) during oxygen- and air-driven jet nebulization, oxygen being added through a nasal device, and to compare the values observed with those measured during standard oxygen therapy.
Methods:
An endotracheal tube was inserted into the distal tracheal extremity of a cadaveric head and neck specimen and connected to a pump, simulating different respiratory patterns. FiO(2) was measured using an electrochemical oxygen analyzer under different nebulization and oxygen delivery conditions. Variables were compared using canonical analysis and analysis of simple and multiple variance.
Results:
FiO(2) was significantly influenced by the mode of oxygen delivery (p = 0.001). The highest FiO(2) was observed when oxygen was delivered via a nasopharyngeal catheter associated with air-driven jet nebulization. For oxygen flow rates of 12 and 15 L/min, a nasal cannula combined with air-driven jet nebulization resulted in a similar FiO(2). The FiO(2) was significantly lower in the case of oxygen-driven jet nebulization. The FiO(2) decreased with increasing respiratory rate (p < 0.001) and tidal volume (p < 0.001).
Conclusions:
Oxygen delivery through a nasal device during air-driven jet nebulization significantly increases the FiO(2), whereas oxygen-driven jet nebulization dramatically decreases FiO(2) compared with standard oxygen therapy.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...