Related Experiment Video
Updated: Jun 22, 2026

A Method for Evaluating Timeliness and Accuracy of Volitional Motor Responses to Vibrotactile Stimuli
Published on: August 2, 2016
The sources of two components of variance: an example of multifinger cyclic force production tasks at different
Jason Friedman1, Varadhan Skm, Vladimir M Zatsiorsky
1Department of Kinesiology, The Pennsylvania State University, University Park, PA 16802, USA.
Abstract:
In a multifinger cyclic force production task, the finger force variance measured across trials can be decomposed into two components, one that affects the combined force output ("bad variance") and one that does not ("good variance"). Previous studies have found similar time patterns of "bad variance" and force rate leading to an approximately linear relationship between them. Based on this finding and a recently developed model of multifinger force production, we expected the "bad variance" during cyclic force production to increase monotonically with the rate of force change, both within a cycle and across trials at different frequencies. Alternatively, "bad variance" could show a dependence on task frequency, not on actual force derivative values. Healthy subjects were required to produce cyclic force patterns to prescribed targets by pressing on unidimensional force sensors, at a frequency set by a metronome. The task was performed with only the index finger, and with all four fingers. In the task with all four fingers, the "good variance" increased approximately linearly with an increase in the force magnitude. The "bad variance" showed within-a-cycle modulation similar to that of the force rate. However, an increase in the frequency did not lead to an increase in the "bad variance" that could be expected based on the natural relationships between action frequency and the rate of force change modulation. The results have been interpreted in the framework of an earlier model of multifinger force production where "bad variance" is a result of variance of the timing parameter. The unexpected lack of modulation of the "bad variance" with frequency suggests a drop in variance of the timing parameter with increased frequency. This mechanism may serve to maintain a constant acceptable level of variance under different conditions.
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Forced Oscillations
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Work and Energy for Variable Forces
Concept of Resonance and its Characteristics
Two-Dimensional Force System: Problem Solving
The first step to solving a two-dimensional force system problem is to draw a free-body diagram of the object under consideration. This diagram helps identify all the external forces acting on the object, including their...

