Related Experiment Video
Updated: Jun 22, 2026

Ion-Exchange Membranes for the Fabrication of Reverse Electrodialysis Device
Published on: July 20, 2021
Electrodialysis with bipolar membrane for regeneration of a spent activated carbon
1Silicon Technology Development Unit, 2, Bd Frantz Fanon BP140, Merveilles 16200, Algeria. nadjibdrouiche@yahoo.fr
Abstract:
The main purpose of the present work was to develop a treatment method to regenerate granular adsorbent beds saturated with H(2)S by utilizing three electrodialysis compartments equipped with a cation or an anion exchange membrane or a bipolar membrane. Three electrodialysis compartments were utilized under various experimental parameters to determine the optimum conditions for the recovery of column particles saturated by H(2)S. The desulphurization operation is achieved with the extent of extraction close to 90% and an electric current density of about 30%. Use of the bipolar membrane makes it possible to regenerate the saturated adsorbent granules without adding chemical products. Since the only reagent was electricity, the projected economics are very attractive.
Related Concept Videos
Potentiometry: Membrane Electrodes
Dialysis
Ion Exchange
Electrolysis
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...