Related Experiment Video
Updated: Jun 22, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
Assessment of humidity and temperature sensors and their application to seating
P W McCarthy1, Z Liu, A I Heusch
1University of Glamorgan, HeSAS, Innovation house, Pontypridd CF371DL, UK. pwmccart@glam.ac.uk
Abstract:
Humidity and temperature are considered to be important factors in designing comfortable seat surfaces. A small number of studies have attempted to address this;however the methods used were limited regarding the placement of their sensors. This study aimed to design a sensor array system to investigate changes in humidity and temperature for eventual use in the study of factors affecting sitting comfort and incontinence detection. The system was subjected to three types of experiments: sensor response verification, thermal radiation testing and in situ trials. The variance in output within each type of sensor was small (+3.5% and +0.38 degrees C) and there was no apparent change to the variance in output of the sensors, when used in air or on a foam cushion loaded with a 50 kg sand bag (p > 0.1). In the human sitting experiments, although the profile from sensors under the thighs and ischial tuberosities were similar, the magnitude of change could be affected by position and body mass of the subject. This was especially noticeable with the sensors under the coccyx. These results support the use of multiple sites for sensor placement over the use of a single site when studying these parameters at the interface between subject and seating material at the seat base.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...