Related Experiment Video
Updated: Jun 22, 2026

Parameterizing V-notch Weir Equations for Flow Monitoring in a Drainage Control Structure
Published on: April 25, 2025
P controller calibration for the real time control of moveable weirs in [corrected] sewer channels
A Campisano1, E Creaco, C Modica
1Dipartimento di Ingegneria Civile e Ambientale, Università di Catania, 95125 Catania, Italy. acampisa@dica.unict.it
Abstract:
In this paper, a detailed study on the local real time control of moveable sharp-crested weirs in sewer channels is presented. Firstly, an experimental analysis aimed at determining the hydraulic behaviour of the regulator under both free flow and submerged flow conditions was carried out. Then, a numerical investigation into the calibration of proportional (P) controllers for the weir control was performed. In particular, suitable values were evaluated for the controller proportional parameter in order to obtain quick regulations and avoid the occurrence of permanent water level oscillations behind the weir. A dimensionless approach was adopted for the generalisation of the results.
Related Concept Videos
Weir: Problem Solving
Weir
Rapidly Varying Flow
Design Example: Design of an Irrigation Channel
Net Change Theorem
Design Example: Creating a Hydraulic Model of a Dam Spillway