Theoretical comparison of the sensitivity of molecular contrast optical coherence tomography techniques
Abstract:
Molecular contrast optical coherence tomography (MCOCT) is an extension of OCT in which contrast resulting from the interaction of light with a contrast agent, leads to the enhanced visualization of a specific morphology or biochemical process in a target specimen. In order to improve the sensitivity and specificity of MCOCT, several spectroscopic techniques have recently been introduced which depend upon coherent detection of scattered light which has been modified by interaction with the molecules of interest in a sample. These techniques include harmonic generation, coherent anti-Stokes Raman scattering, linear absorption, and several different forms of pump-probe spectroscopy. We have developed a theoretical framework to facilitate the comparison of the sensitivity of different MCOCT techniques. This framework is based upon the observation that since the noise floor is defined by the reference field power in a shot-noise limited OCT system, the relevant comparison among the techniques is isolated to the available molecular contrast signal power and the algorithm used to extract the signal. We have derived theoretical expressions for the signal power and signal-to-noise ratio for the MCOCT techniques described in the literature based on molecular spectroscopy, as well as several new techniques introduced here.
Related Concept Videos
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...