Related Experiment Video
Updated: Jun 22, 2026

07:56
A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
Ultra-stable, widely tunable and absolutely linked mid-IR coherent source
I Galli1, S Bartalini, P Cancio
1Istituto Nazionale di Ottica Applicata- CNR, Firenze, FI, Italy.
Optics Express
|June 10, 2009
Summary
Researchers developed a new tunable coherent source with a 10-Hz linewidth. This precise optical frequency tool enhances molecular physics research by achieving high absorption sensitivity.
Area of Science:
- Atomic, Molecular, and Optical Physics
- Spectroscopy
- Quantum Optics
Background:
- Precise frequency control is crucial for advanced molecular spectroscopy.
- Existing coherent sources often lack the required tunability or linewidth for certain applications.
Purpose of the Study:
- To develop a novel coherent source with exceptional spectral characteristics.
- To demonstrate its capability for high-sensitivity absorption measurements.
Main Methods:
- Implementing a phase-lock scheme to an optical frequency-comb synthesizer.
- Coupling the source to a high-finesse optical cavity.
- Tuning the source across the 4–4.5 micrometer wavelength range.
Main Results:
- Achieved a 10-Hz intrinsic linewidth for the coherent source.
- Demonstrated presettable absolute frequency control.
- Obtained a short-term absorption sensitivity of 1.3 x 10(-11) cm(-1)Hz,(-1/2) when cavity-enhanced.
Conclusions:
- The developed coherent source offers unique spectral features for precision measurements.
- It serves as a powerful tool for molecular physics and spectroscopy.
- The high sensitivity enables new possibilities in trace gas detection and fundamental studies.
Related Concept Videos
IR Frequency Region: X–H Stretching
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in the 3500–3100 cm−1 range. Even though both O−H and N−H bonds vibrate at a similar...
IR Absorption Frequency: Hybridization
Hydrocarbons such as alkanes, alkenes, and alkynes show characteristic C–H stretching absorption bands. These IR stretching frequencies depend on the hybridization of the involved carbon atom and can be explained in terms of the s character of each hybridized atomic orbital.
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
IR Spectrum
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
IR Absorption Frequency: Delocalization
Electron delocalization refers to the distribution of electrons across multiple atoms within a molecule rather than being confined to a single atom or bond. This phenomenon is common in systems with conjugated bonds—structures where alternating single and double bonds allow π-electrons to move freely across the network. The movement of electrons stabilizes the molecule and can affect various chemical properties, including vibrational frequencies observed in IR spectroscopy.
In IR spectroscopy,...
In IR spectroscopy,...
