Related Experiment Video
Updated: Jun 22, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
In-tube solid-phase microextraction and liquid chromatography using a monolithic column for the selective
M C Prieto-Blanco1, P López-Mahía, P Campíns-Falcó
1Departamento Química Analítica, Facultade de Ciencias, Universidade da Coruña, Campus da Zapateira, E-15071 A Coruña, Spain.
Abstract:
The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 microm thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed through the capillary, and 100 microL of water was later used for cleaning and filling the capillary. After, the injection was effected and the desorption of the derivative from the capillary was carried out in the dynamic mode using the mobile phase. Chromatographic separation was performed in less than 2 min using a monolithic silica column Onyx (100 mm x 3.0 mm i.d.) under isocratic conditions. The effect of several parameters affecting derivatization and IT-SPME was investigated. The quantification of EDA was realized over the range of 0.07-2 microg/mL with adequate linearity, accuracy, and reproducibility, and the limit of detection was 20 ng/mL. The method is rapid and low in cost, and sample handling and organic solvent consumption have been minimized. Its application to polymeric cationic surfactants used in water treatment allowed the selective quantification of residual EDA at low microgram per milliliter levels of concentration without off-line preconcentration.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
Analyte Adsorption and Distribution