Comparison of different quantification methods of late gadolinium enhancement in patients with hypertrophic

Mateusz Spiewak1, Lukasz A Malek, Jolanta Misko

  • 1First Department of Coronary Artery Disease, Magnetic Resonance Unit, Institute of Cardiology, ul. Alpejska 42, 04-628 Warsaw, Poland. mspiewak@ikard.pl

Insights

Quantifying late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM) using a 6SD threshold best matches visual assessment. This method offers reliable LGE mass estimation in HCM patients.

Area of Science:

  • Cardiovascular Imaging
  • Cardiac MRI
  • Quantitative Analysis

Background:

  • Quantification of late gadolinium enhancement (LGE) in hypertrophic cardiomyopathy (HCM) lacks a standardized approach.
  • Accurate LGE assessment is crucial for understanding disease severity and patient outcomes.

Purpose of the Study:

  • To compare various quantification techniques for LGE in patients diagnosed with HCM.
  • To identify the most reliable method for LGE mass measurement in this population.

Main Methods:

  • Cardiac MRI was performed on 33 HCM patients.
  • LGE was quantified using visual assessment and multiple thresholding techniques (1SD to 6SD, FWHM).
  • Signal intensity (SI) of remote myocardium and maximal SI were used for threshold calculations.

Main Results:

  • LGE was detected in 78% of patients.
  • Median LGE mass varied significantly across methods, with 1SD yielding the highest and FWHM the lowest values.
  • The 6SD threshold demonstrated the strongest correlation with visual assessment (rho=0.956, p<0.0001), showing no significant difference.

Conclusions:

  • A threshold of 6SD above the mean SI of remote myocardium provides the best agreement with visual assessment for LGE quantification in HCM.
  • This method offers a reliable approach for LGE mass estimation in clinical practice.
Abstract