Related Experiment Video
Updated: Jun 22, 2026

Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer
Published on: November 4, 2009
Estimation of peptide concentration by a modified bicinchoninic acid assay
Krishan N Kapoor1, Danielle T Barry, Robert C Rees
1School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK.
Abstract:
Although biuret based protein assays are theoretically applicable to peptide measurement, there is a high level of interpeptide variation, determined largely by peptide hydrophobicity. This variation in peptide reactivity can be significantly reduced by heat-denaturation of peptides at 95 degrees C for 5 min in the presence of 0.1 M NaOH containing 1% (w/v) SDS, prior to incubation for 30 min at 37 degrees C in BCA standard working reagent. This modification to the standard bicinchoninic acid (BCA) assay protocol allows for an accurate, rapid, and economical estimation of the peptide concentration within an unknown sample.