Accuracy of stent measurements using ECG-gated greyscale intravascular ultrasound images: a validation study
Ryan K Kaple1, Kenichi Tsujita, Akiko Maehara
1The Cardiovascular Research Foundation, Columbia University Medical Center, New York City, NY, USA.
Abstract:
Greyscale intravascular ultrasound (IVUS) is an accurate tool for measuring stent dimensions and residual disease at the stent edge. Electrocardiographically (ECG)-gated IVUS is used in evolving second-generation IVUS systems, but this modality provides fewer greyscale cross-sectional images, and its accuracy to measure stent dimensions has not been assessed. This study was designed to validate the use of ECG-gated greyscale IVUS in measuring minimum stent area (MSA), stent length and reference dimensions compared to standard greyscale IVUS data. IVUS imaging was performed after drug-eluting stent implantation in 53 target lesions in 48 patients with acute coronary syndrome. The IVUS catheter was mechanically withdrawn at 0.5 mm/s, standard greyscale images were collected at 10 frames/s, and ECG-gated greyscale images were constructed from R-wave gated images. The MSA measured 6.20 +/- 1.75 mm(2)vs. 5.98 +/- 1.55 mm(2) on standard greyscale and ECG-gated greyscale IVUS, respectively (R(2) = 0.91, p = 0.005). The MSA position (R(2) = 0.66, p = 0.179) and stent length (R(2) = 0.99, p = 0.435) measurements were similar between modalities. Proximal reference vessel area was larger by ECG-gated IVUS, but proximal reference lumen and distal reference measurements were similar. Bland-Altman plots demonstrated good agreement between modalities. In conclusion, ECG-gated greyscale IVUS provides accurate and reliable measurements of stent length, area and reference segment plaque burden after stent implantation and is not inferior to standard greyscale IVUS.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT