Related Experiment Video
Updated: Jun 22, 2026

An Approach to Point-Of-Care Ultrasound Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Volume imaging in the abdomen with ultrasound: how we do it
Stephanie R Wilson1, Chander Gupta, Michael Eliasziw
1Department of Diagnostic Imaging, University of Calgary Foothills Medical Centre, 1403 29 St., NW, Calgary, AB T2N 2T9, Canada. stephanie.wilson@albertahealthservices.ca
Objective:
The objective of our study was to evaluate the feasibility of volumetric acquisition of the abdominal organs using performance guidelines that we developed in our preliminary experience.
Materials And Methods:
Mechanical volumetric acquisitions of each abdominal organ, including the liver, gallbladder, pancreas, kidneys, spleen, bowel, and aorta, were performed in 200 consecutive patients.
Results:
One thousand four hundred fifty-four volume data sets were graded for feasibility of performance and technical adequacy from I (impossible, incomplete) to V (excellent, complete). The most successfully imaged organ was the right kidney (grades IV and V, 95.0%) and the least successfully imaged, the spleen (grades IV and V, 69.0%). Very good to excellent grades (IV and V) were obtained in 1,215 (83.6%) of the 1,454 volumes. One hundred twelve (7.7%) of the 1,454 volumes were failures (grades I and II). The three organs with the highest success compared with the right kidney were the left kidney, gallbladder, and liver. The data sets of all the other organs showed a statistically significant difference in the feasibility of performance from the right kidney. Liver acquisition failures were associated with end-stage liver cirrhosis (n = 6), fatty liver (n = 3), and obesity (n = 3). Other acquisition failures, similar to conventional sonography, were associated with bowel gas interference and poor acoustic window. The technical limitations include poor resolution in the B and C planes and a limited range of frequencies; these limitations can be overcome in the future with matrix transducers and introduction of the technology to a broader frequency range.
Conclusion:
Volumetric acquisition in the abdomen performed using defined guidelines is feasible with recognized limitations. Technology advances will improve this imaging technique in the future.
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
