Abstract:
Real time closed loop control of plasma assisted semiconductor manufacturing processes has received significant attention in recent years. Therefore we have developed and tested a customized optical sensor based on buffer gas (argon) actinometry which has been used to determine relative densities of atomic and molecular oxygen in an Ar/O(2) radio-frequency ICP chamber. The operation and accuracy of our optical sensor compared favorably with a high resolution commercial spectrometer but at lower cost and exhibited improved actinometric performance over a low resolution commercial spectrometer. Furthermore, threshold tests have been performed on the validity of buffer gas based actinometry in Ar/O(2) ICP plasmas where Ar is no longer a trace gas through Xe actinometry. The plasma conditions for which this customized optical sensor can be used for closed loop control have been established.