Feasibility of using tissue Doppler velocities in stress echo during upright bicycle exercise
Anders Hovland1, Hanne Bjørnstad, Jan Prytz
1Coronary Care Unit, Department of Internal Medicine, Nordland Hospital, Bodø, Norway. anders.w.hovland@gmail.com
Background And Aim:
There are several studies on myocardial tissue Doppler velocities during dobutamine stress, but few studies on the same parameters during bicycle exercise. We wanted to examine how sample sites affected velocities, beat-to-beat variability and segments eligible for analysis.
Methods:
Twenty patients with normal coronary arteries were included in the study. Echocardiograms were obtained at rest and at peak exercise on the exercise bike and were analyzed off line by two independent raters.
Results And Conclusions:
Tissue velocities decreased from base to apex. Mean difference between the raters was-0.02 cm/sec at rest and 0.45 cm/sec during exercise. Peak-to-peak variability was lowest in the mitral ring during rest (10-14%) and increased at peak exercise (15-21%). The proportion of segments eligible for analysis was 84% in the septum and 67% in the anterior wall during exercise. Thus, in patients with normal coronary arteries, tissue Doppler velocities decrease from base toward the apex during bicycle exercise. Interrater agreement is reduced during exercise and beat-to-beat variability is lowest in the mitral ring.
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...