Related Experiment Video
Updated: Jun 22, 2026

Sediment Core Extrusion Method at Millimeter Resolution Using a Calibrated, Threaded-rod
Published on: August 17, 2016
Development and calibration of a gamma-ray density-meter for sediment-like materials
1Nuclear Geophysics Division, Kernfysisch Versneller Instituut, Groningen, The Netherlands. marko.maucec@halliburton.com
Abstract:
The core-logger PHAROS was designed at Kernfysisch Versneller Instituut, Groningen, the Netherlands to measure activity concentration of sediment like materials. As the core logger was calibrated for a single material density the variations in the density profile in the scanned core can result in erroneous estimations of activity concentrations. To overcome this, a density-meter was developed and implemented on PHAROS. The density measurement should be non-invasive and should cover a wide range of sediment like materials. The most suitable approach is to deploy gamma-ray transmission technique, where the intensity of non-attenuated photons after traversing the core is directly related to its density. Due to the overall complexity of radiation transport through sediment media, the design of the density-meter was assisted by Monte Carlo simulations. They were deployed to model sophisticated and time-consuming experiments in the process of designing the (137)Cs-based source, to generate the pulse-height response functions of the bismuth-germanate (BGO) scintillator and to estimate the systematic uncertainty induced by the core displacement in the process of the measurement. Moreover, the Monte Carlo simulations have demonstrated as a reliable complementary tool for the generation of PHAROS detector calibration curves. The designed density-meter of PHAROS core-logger indicates to be adequate to estimate densities ranging from approximately 1.6 to approximately 2.7gcm(-3) with the systematic uncertainty within 3%.
More Related Videos
08:09Measuring and Mapping Patterns of Soil Erosion and Deposition Related to Soil Carbonate Concentrations Under Agricultural Management
Published on: September 12, 2017
12:03Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Microbial Growth Measurement: Indirect Methods