Related Experiment Video
Updated: Jul 26, 2026

A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
Validation of a personal radon monitor for use in residential 22Rn exposure studies
B R Litt1, J M Waldman, N H Harley
1New Jersey Department of Environmental Protection, Division of Science and Research, Trenton 08625.
Abstract:
A personal radon monitor (PRM) has been developed and validated for use in studies of residential 222Rn exposure. A pilot study was performed in six New Jersey homes with elevated Rn concentrations. Occupants wore PRMs, and identical monitors were placed in many rooms of the home. Extensive assessment of PRM performance has been done. A simple model for personal Rn exposure has been tested and measured occupant exposures have been compared with stationary Rn measurements. The PRM works well, with precision limited by the counting error in the exposure range examined (2-100 kBq m-3 h). The PRM sensitivity is 2.2 kBq m-3 h, and its efficiency is 2.6 tracks (kBq m-3 h)-1 per 81 mm2 film.