Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Bedside prediction of increased filling pressure using acoustic electrocardiography
Sean P Collins1, Christopher J Lindsell, Michael C Kontos
1University of Cincinnati, Cincinnati, OH, USA. collinsp@ucmail.uc.edu
Background:
Patients presenting with acute dyspnea are often a diagnostic dilemma. A bedside tool that accurately and rapidly identifies increased left ventricular (LV) filling pressure would be helpful. We evaluated acoustic electrocardiography for this purpose.
Methods:
We pooled 3 cohorts of patients for this analysis. Inclusion criteria required acoustic electrocardiography and echocardiography within 4 hours of each other. Increased LV filling pressure was defined as a pseudonormal or restrictive filling pattern on echocardiography. Area under the receiver operating characteristic curve (AUC) assessed multivariable model accuracy.
Results:
The median age of the 324 patients was 61 years (range, 19-90 years), 67% were male, and 82% had a history of heart failure. The final multivariable model included mean LV systolic time, S(3) score, maximum negative area of the P wave, and the QTc interval. The AUC was 0.83 (95% confidence interval, 0.78-0.88). Although B-type natriuretic peptide (BNP) was an independent predictor of estimated increased filling pressure when considered alone (odds ratio = 1.002, 95% confidence interval, 1.000-1.003, P = .002), when added to the acoustic model, it did not improve overall model accuracy. In the subset of patients with indeterminate BNP levels (100-500 pg/mL), the acoustic model was more accurate than BNP (AUC = 0.82 vs 0.71).
Conclusions:
Bedside acoustic electrocardiography predicted echocardiographic correlates of increased pressures with high accuracy. For patients with an indeterminate BNP level (100-500 pg/mL), the acoustic electrocardiography model was superior to BNP. Prospective model validation is warranted.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...