Related Experiment Video
Updated: Jun 22, 2026

Standards for Quantitative Metalloproteomic Analysis Using Size Exclusion ICP-MS
Published on: April 13, 2016
Trace iodine quantitation in biological samples by mass spectrometric methods: the optimum internal standard
Jason V Dyke1, Purnendu K Dasgupta, Andrea B Kirk
1Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX 79409-1061, USA.
Abstract:
Accurate quantitation of iodine in biological samples is essential for studies of nutrition and medicine, as well as for epidemiological studies for monitoring intake of this essential nutrient. Despite the importance of accurate measurement, a standardized method for iodine analysis of biological samples is yet to be established. We have evaluated the effectiveness of (72)Ge, (115)In, and (129)I as internal standards for measurement of iodine in milk and urine samples by induction coupled plasma mass spectrometry (ICP-MS) and of (35)Cl(18)O(4)(-), (129)I(-), and 2-chlorobenzenesulfonate (2-CBS) as internal standards for ion chromatography-tandem mass spectrometry (IC-MS/MS). We found recovery of iodine to be markedly low when IC-MS/MS was used without an internal standard. Percent recovery was similarly low using (35)Cl(18)O(4) as an internal standard for milk and unpredictable when used for urine. 2-Chlorobenzebenzenesulfonate provided accurate recovery of iodine from milk, but overestimated iodine in urine samples by as much as a factor of 2. Percent recovery of iodine from milk and urine using ICP-MS without an internal standard was approximately 120%. Use of (115)In predicted approximately 60% of known values for both milk and urine samples. (72)Ge provided reasonable and consistent percent recovery for iodine in milk samples (approximately 108%) but resulted in approximately 80% recovery of iodine from urine. Use of (129)I as an internal standard resulted in excellent recovery of iodine from both milk and urine samples using either IC-MS/MS and ICP-MS.
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Tandem Mass Spectrometry
Mass Spectrometry: Isotope Effect
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
