Related Experiment Video
Updated: Jun 22, 2026

A Single-Channel and Non-Invasive Wearable Brain-Computer Interface for Industry and Healthcare
Published on: July 7, 2023
Visual stimuli for the P300 brain-computer interface: a comparison of white/gray and green/blue flicker matrices
Kouji Takano1, Tomoaki Komatsu, Naoki Hata
1Cognitive Functions Section, DRSF, Research Institute of National Rehabilitation Center for Persons with Disabilities, Tokorozawa, Saitama, Japan.
Objective:
The white/gray flicker matrix has been used as a visual stimulus for the so-called P300 brain-computer interface (BCI), but the white/gray flash stimuli might induce discomfort. In this study, we investigated the effectiveness of green/blue flicker matrices as visual stimuli.
Methods:
Ten able-bodied, non-trained subjects performed Alphabet Spelling (Japanese Alphabet: Hiragana) using an 8 x 10 matrix with three types of intensification/rest flicker combinations (L, luminance; C, chromatic; LC, luminance and chromatic); both online and offline performances were evaluated.
Results:
The accuracy rate under the online LC condition was 80.6%. Offline analysis showed that the LC condition was associated with significantly higher accuracy than was the L or C condition (Tukey-Kramer, p < 0.05). No significant difference was observed between L and C conditions.
Conclusions:
The LC condition, which used the green/blue flicker matrix was associated with better performances in the P300 BCI.
Significance:
The green/blue chromatic flicker matrix can be an efficient tool for practical BCI application.