Related Experiment Video
Updated: Jun 21, 2026

A Method for Systematic Electrochemical and Electrophysiological Evaluation of Neural Recording Electrodes
Published on: March 3, 2014
Real-time volume imaging using a crossed electrode array
Christine E M Démoré1, Andrew W Joyce, Kieran Wall
1Institute for Medical Science and Technology, University of Dundee, Scotland. cdemore@ieee.org
Abstract:
This paper describes a unique crossed electrode array for real-time volume ultrasound imaging. By placing orthogonal linear array electrode patterns on the opposite sides of a hemispherically shaped composite transducer substrate, a 2-D array can be fabricated using a small fraction of the elements required for a traditional 2-D array. The performance of the array is investigated using a computer simulation of the radiation pattern. We show that by using a 288-element crossed electrode pattern it is possible to collect large field of view volume images (60 degrees x 60 degrees sector) at real-time frame rates (>20 volume images/s), with image contrast and resolution comparable to what can be obtained using a conventional 128-element linear phased array.