Three-channel all-optical routing in a Pr3+:Y2SiO5 crystal

Hai-Hua Wang1, Yun-Fei Fan, Rong Wang

  • 1College of Physics, Jilin University, Changchun 130023, PR China.

Optics Express
|July 8, 2009
PubMed

Related Concept Videos

The Y-to-Y Circuit01:19

The Y-to-Y Circuit

In a balanced four-wire wye-to-wye system, the arrangement involves wye-connected sinusoidal voltage sources and loads, connected through a neutral wire that links the neutral nodes of the source and load. The load impedance is connected across each phase of the load. The wye-connected source can be connected to the wye-connected load in four-wire and three-wire arrangements. A three-phase system is considered balanced when the load on each phase is equal, leading to uniform current flow and...
LC Circuits01:21

LC Circuits

An LC circuit consists of an inductor and a capacitor, either in series or parallel. Consider a charged capacitor connected with an inductor in series. Before the switch is closed, all the energy of the circuit is stored in the electric field of the capacitor. When the switch is closed, the capacitor begins to discharge, producing a current in the circuit. The current, in turn, creates a magnetic field in the inductor. Because of the induced emf in the inductor, the current cannot change...
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
Cascaded Op Amps01:16

Cascaded Op Amps

Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
Clipper Circuit01:18

Clipper Circuit

A clipper circuit is a fundamental wave-shaping device that harnesses the unique properties of diodes to alter and control waveform characteristics. This technology is widely used in electronic devices, especially in television and radar communication systems, where it enhances waveform modulation in both transmitters and receivers.
The operation of a clipper circuit can be exemplified by analyzing a dual-clipper configuration setup that integrates two ideal diodes, each paired with a biasing...