Related Experiment Video
Updated: Feb 13, 2026

Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice
Published on: June 15, 2020
Global ST-segment elevation associated with impending cardiac rupture during diagnostic cardiac catheterization
Tadayuki Kadohira1, Yoshio Kobayashi, Yuriko Niitsuma
1Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, Chiba, Japan.
Cardiac rupture during cardiac catheterization is rare but life-threatening. This case report details a rare instance of cardiac rupture during diagnostic cardiac catheterization, identified by global ST-segment elevation.
Area of Science:
- Cardiology
- Interventional Cardiology
- Medical Device Technology
Background:
- Cardiac catheterization is a common diagnostic procedure.
- Cardiac rupture is a rare but severe complication.
- Advancements in catheter technology aim to improve patient safety.
Observation:
- A 4F pigtail catheter and a 0.035" flexible guidewire were used.
- The patient exhibited global ST-segment elevation.
- These findings indicated impending cardiac rupture.
Findings:
- The case report documents a rare occurrence of cardiac rupture during diagnostic cardiac catheterization.
- Global ST-segment elevation served as a critical indicator of the impending rupture.
- The specific guidewire and catheter combination was implicated in the event.
Implications:
- Highlights the persistent risk of cardiac rupture despite technological advancements.
- Emphasizes the importance of recognizing subtle electrocardiographic changes during catheterization.
- Suggests a need for continued vigilance and potential refinement of procedural techniques and device selection.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...