Non-invasive central venous pressure measurement by compression ultrasound--a step into real life
Christoph Thalhammer1, Martin Siegemund, Markus Aschwanden
1Department of Angiology, University Hospital, Zurich, Switzerland. christoph.thalhammer@usz.ch
Aim Of The Study:
Information on central venous pressure (CVP) is helpful in clinical situations like cardiac failure and sepsis. Compression ultrasound (CU) of a forearm vein has been shown to be a reliable method for CVP measurement when assessed by experienced personal under study conditions. To test the hypothesis, that CU can be reliably used for CVP measurement after a training program and using a portable ultrasound system, we investigated feasibility and accuracy of CU, comparing the results of vascular experts vs. trainees as well as high-end vs. a portable ultrasound system.
Methods:
CU with non-invasive CVP measurement (CVP(ni)) was performed by four investigators in 50 patients of an intensive care unit and compared with invasive CVP measurement (CVP(i)).
Results:
Feasibility was between 88 and 92% in the different investigator groups. CVP(ni) measurement showed a significant linear correlation (r=0.58-0.68; p<0.001) with CVP(i) in all groups. Mean difference between CVP(i) and CVP(ni) was 2.4+/-3.1mmHg and similar between the investigators. No differences were observed between measurements done by vascular experts and trainees, as well as between high-end and portable ultrasound systems. Further we demonstrated, that CU is able to detect changes in CVP during the respiratory cycle.
Conclusions:
After a training program CU can be used by non-vascular clinician for reliable CVP measurement with good quality portable systems. Furthermore, respiratory changes in CVP are detectable by CU. These data suggest CU to be an efficient method for measuring CVP under real life conditions.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Measurement of Blood Pressure
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):