Related Experiment Video
Updated: Jun 21, 2026

Reservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography
Published on: February 25, 2015
Fourier-wavelet regularization of phase retrieval in x-ray in-line phase tomography
Max Langer1, Peter Cloetens, Françoise Peyrin
1European Synchrotron Radiation Facility, Grenoble Cedex. France. max.langer@esrf.fr
Abstract:
Phase sensitive x-ray imaging extends standard x-ray microscopy techniques by offering up to a thousand times higher sensitivity than absorption-based techniques. If an object is illuminated with a sufficiently coherent beam, phase contrast is achieved by moving the detector downstream from the object. There is a quantitative relationship between the phase shift induced by the object and the recorded intensity. This relationship can be used to retrieve the phase shift induced by the object through the solution of an inverse problem. Since the phase shift can be considered as a projection through the 3D refractive index, the latter can be reconstructed using standard tomographic inversion techniques. However, the determination of the phase shift from the recorded intensity is an ill-posed inverse problem. We investigate the application of Fourier-wavelet regularized deconvolution (ForWaRD) to this problem. The method is evaluated using simulated and experimental data and is shown to increase the quality of reconstructions, in terms of normalized RMS error and compared with standard Tikhonov regularization, at a three times increase in computational cost.
More Related Videos
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Continuous -time Fourier Transform
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...

