The Use of Gas Chromatography to Analyze Compositional Changes of Fatty Acids in Rat Liver Tissue during Pregnancy
Published on: March 13, 2014
Determination of curcumol in rat plasma by capillary gas chromatography with a hydrogen flame ionization detector
1Institute of Materia Medcia, Chinese Academy of Medical Sciences, 1 Xiannongtan Street, Beijing, People's Republic of China. ylliu@imm.ac.cn
Abstract:
A simple and sensitive capillary gas chromatography with a hydrogen flame ionization detector (GC-FID) method was developed for the determination of curcumol in rat plasma. From a variety of compounds and solvents tested, buagafuran was selected as the internal standard (IS) and acetonitrile was found to be the best protein precipitation agent and solvent for extracting curcumol from plasma and tissues samples. (Buagafuran was used as an internal standard. Curcumol was extracted by a protein precipitation with acetonitrile.) The samples were determined by GC on an HP-5 column (30.0 m x 0.32 mm, 0.25 microm); inlet volume 2 microL; split ratio 10 : 1; inlet temperature 250 degrees C; oven temperature 180 degrees C; flow 1.0 mL/.min; FID 250 degrees C; carrier gas N(2). The resulting retention times of curcumol and IS were 6.0 and 9.5 min. There was good linearity over the range 0.133-133.3 microg/mL (r = 0.9999) in plasma samples. The method recoveries were 97.7-102.0% in plasma, and the intra- and inter-day variances (RSD) were less than 15% in all cases. The GC method was applied to develop a pharmacokinetics study in which experimental rats received a single administration of curcumol by intravenous injection.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Flame Photometry: Lab