Effects of acute variation of dialysate calcium concentrations on arterial stiffness and aortic pressure waveform

Amélie LeBeouf1, Fabrice Mac-Way, Mihai Silviu Utescu

  • 1Division of Nephrology, Research Center of CHUQ, L'Hôtel Dieu de Québec Hospital and Faculty of Medicine, Laval University, Quebec, QC, Canada.

Insights

Dialysis calcium concentration (D(Ca)) significantly impacts arterial stiffness and pulse wave profiles in hemodialysis patients. Adjusting D(Ca) can influence vascular health, warranting further long-term investigation.

Area of Science:

  • Nephrology
  • Cardiovascular Physiology
  • Mineral Metabolism

Background:

  • Abnormal mineral metabolism in chronic kidney disease (CKD) contributes to vascular calcification and arterial stiffness.
  • The effect of dialysis calcium concentration (D(Ca)) on arterial stiffness and aortic pressure waveform remains understudied.
  • This study investigates the impact of acute D(Ca) modification on arterial stiffness and central pulse wave profile (cPWP) in hemodialysis (HD) patients.

Purpose of the Study:

  • To evaluate the acute effects of varying dialysis calcium concentrations (1.00, 1.25, and 1.50 mmol/L) on arterial stiffness and cPWP in HD patients.
  • To assess the relationship between D(Ca), serum ionized calcium (iCa) levels, and vascular parameters.
  • To determine the influence of D(Ca) on pulse wave velocity (PWV) and wave reflection timing.

Main Methods:

  • A randomized Latin square cross-over design was employed.
  • Three D(Ca) levels (1.00, 1.25, 1.50 mmol/L) were tested sequentially with a 7-day washout period.
  • Measurements included cPWP, carotido-femoral (c-f) and carotido-radial (c-r) PWV, plasma iCa, intact parathyroid hormone (PTH), and mean blood pressure (BP) before and after HD sessions.

Main Results:

  • Higher D(Ca) correlated with increased post-HD c-f PWV, c-r PWV, and mean BP.
  • Earlier wave reflection timing (Tr) was observed with higher D(Ca).
  • Increased serum iCa levels were significantly associated with increased c-f PWV and c-r PWV.

Conclusions:

  • Acute changes in serum iCa concentration, influenced by D(Ca) even within physiological ranges, are linked to measurable alterations in arterial stiffness and cPWP.
  • Further long-term studies are essential to understand the sustained effects of D(Ca) modulation on vascular parameters in HD patients.
Abstract

Related Concept Videos

Antihypertensive Drugs: Action of Calcium Channel Blockers01:18

Antihypertensive Drugs: Action of Calcium Channel Blockers

Calcium ions are essential to contract smooth muscle cells in blood vessels. They enter these cells through voltage-dependent calcium channels, specifically L-type calcium channels in the cell membrane. These L-type calcium channels are integral to the excitation-contraction coupling process in smooth muscle. When a stimulus is received by smooth muscle cells, their membrane depolarizes. This alteration in membrane potential instigates the opening of L-type calcium channels. As a result,...
Feedback Regulation of Calcium Concentration01:27

Feedback Regulation of Calcium Concentration

Calcium is an essential signaling molecule required for various cellular functions. Calcium pumps and ion channels on cell and organellar membranes, such as those on the endoplasmic reticulum (ER), regulate calcium concentrations inside the cell. They remain closed, keeping the cytosolic calcium levels low at a resting state.
Various transmembrane receptors, such as G protein-coupled receptors (GPCRs), elicit a response to extracellular signals by increasing cytosolic calcium. Activated GPCRs...
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Special considerations while measuring blood pressure01:28

Special considerations while measuring blood pressure

When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: