Dosimetric comparison of four new design 103Pd brachytherapy sources: optimal design using silver and copper rod
S Hamed Hosseini1, Mahdi Sadeghi, Vahideh Ataeinia
1Agricultural, Medical and Industrial Research School, Nuclear Science and Technology Research Institute, P.O. Box 31485-498, Karaj, Tehran (098)21, Iran.
Abstract:
Four new brachytherapy sources, IRA1-103Pd, IRA2-103Pd, IRA3-103Pd, and IRA4-103Pd, have been developed at Agricultural, Medical, and Industrial Research School and are designed for permanent implant application. With the goal of determining an optimal design for a 103Pd source, this article compares the dosimetric properties of these sources with reference to the authors' earlier IRA-103Pd source. The four new sources differ in end cap configuration and thickness and in the core material, silver or copper, that carries the adsorbed 103Pd. Dosimetric data derived from the authors' Monte Carlo simulation results are reported in accordance with the updated AAPM Task Group No. 43 report (TG-43U1). For each source, the authors obtained detailed results for the dose rate constant lambda, the radial dose function g(r), the anisotropy function F(r, theta), and the anisotropy factor phi(an)(r). In this study, the optimal source IRA3-103Pd provides the most isotropic dose distribution in water with the dose rate constant of 0.678(+/-0.1%) cGy h(-1) U(-1). The IRA3-103Pd design has a silver rod core combined with thin-wall, concave end caps. Finally, the authors compared the results for their optimal source with published results for those of other source manufacturers.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Radiation: Applications
The average...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...