Monte-Carlo simulation of uncertainty in the estimation of 125I in the thyroid
1Health Physics Division, Bhabha Atomic Research Centre, BARC Hospital, Mumbai, India. sharda.bhati@gmail.com
Abstract:
At the Bhabha Atomic Research Centre, a thin (76 mm diameter x 2 mm thickness) NaI (Tl) detector is used for the assessment of (125)I in the thyroid of the radiation workers engaged in the preparation of radio-immunoassay kits. The detector was calibrated using a REMCAL (radiation equivalent manikin calibration) phantom with a known amount of the (125)I activity filled in its thyroidal cavity. Since (125)I emits low-energy photons ranging from 27 to 35.4 keV, its detection efficiency depends on several parameters such as neck-to-detector distance, detector size, unknown tissue thickness overlying (OTT) the thyroid and the shape and size of the thyroid. To account for uncertainties introduced by these factors in the estimation of (125)I, a computer program based on the Monte Carlo photon transport techniques was developed. The program simulates the detector response and the corresponding detection efficiencies using two thyroid models: (1) revised MIRD head phantom and (2) Ulanvosky model. The program has been validated with experimental measurements carried out using a REMCAL phantom. The computed values of uncertainties due to placement errors (+/-0.5 cm) for different detector sizes, differences in the OTT of the thyroid (0.6-2.0 cm) and different thyroid shapes are presented in this paper. The computed values of the calibration factors, determined for the revised MIRD phantom, varied from 5.23 to 1.06 x 10(-2) counts per photon for detector distance of 3-12 cm and from 7.53 to 3.66 x 10(-2) counts per photon for OTT varying from 0.6 to 2.0 cm keeping the detector at a distance of 3 cm. This study shows that the variations in OTT constitute a major source of uncertainty. The computed uncertainties due to various parameters should be taken into account while estimating the thyroidal burden of (125)I in the radiation workers. The feasibility of using coincidence method for absolute determination of the (125)I activity in the thyroid is also discussed in this paper.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Propagation of Uncertainty from Systematic Error
Uncertainty: Overview