Do radiologists agree on the quality of computed tomography enterography?
Kari Ersland1, Jan Terje Kvaløy, Bodil Margrethe Styr
1Department of Radiology, Stavanger University Hospital, Stavanger, Norway.
Abstract:
This study aimed to assess variation between radiologists evaluating the quality of multi-detector computed tomography enterography. For 40 consecutive examinations, three experienced radiologists independently rated the following quality variables: % length of adequately filled bowel, bowel lumen diameters, bowel wall delineation, superior mesenteric vein, and bowel wall enhancement, artefacts, and total quality. We calculated the mean difference between observers with standard deviation (SD) for continuous variables and % total agreement, exact Fleiss kappa, and P-values (McNemar's test) for categorical variables. Depending on bowel segment (duodenum distal to bulb, jejunum, ileum, terminal ileum), mean difference between observers ranged from two to 33 (SD from 11 to 32) for % length of adequately filled bowel judged subjectively, 0-2 (SD 0-3) mm for smallest bowel lumen diameter and 0-4 (SD 3-7) mm for largest bowel lumen diameter. Agreement on bowel wall delineation was 80%/kappa 0.50 in duodenum, 90%/kappa 0.57 in jejunum, 75%/kappa 0.14 in ileum and 88%/kappa 0.17 in terminal ileum, where ratings differed between observers (P < 0.04). Agreement was 65%/kappa 0.18 for bowel wall enhancement judged subjectively. For contrast enhancement measured in Hounsfield Units, mean difference between observers ranged from two to 11 (SD 12-15) in normal jejunum wall and zero to one (SD 4-5) in the superior mesenteric vein depending on observer pair. Agreement was 78%/kappa 0.12 for image artefacts. Rating of total examination quality (good/optimal versus poor/very poor) differed between observers (P < 0.01); agreement was 60%/kappa 0.41. Many subjective evaluations varied between observers. We believe that measurements of bowel lumen diameters and contrast enhancement may be preferable.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...