An electrochemical biosensor for ultratrace terbium based on Tb3+ promoted conformational change of human telomeric G-quadruplex
Related Experiment Video
Updated: Jun 20, 2026

In Vitro Chemical Mapping of G-Quadruplex DNA Structures by Bis-3-Chloropiperidines
Published on: May 12, 2023
Jing Zhang1, Jinghua Chen, Rongchun Chen
1Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, and Department of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China.
Abstract:
A new electrochemical biosensor for the monitoring of ultratrace terbium based on the conformational change of DNA containing a single guanine (G)-rich stretch was described here. The biosensor was fabricated by immobilizing a thiolated DNA containing a single G-rich stretch on the gold surface as probe surface. The G-rich DNA probe was found to be capable of changing its configuration from flexible single-stranded structures to rigid tetramolecular G-quadruplex in the presence of terbium III, which provided a switchable charge transport path for the oxidation of [Fe(CN)(6)](4-). The switchable surface provided a sensing platform for the single-step and reagentless detection of Tb(3+). Using this reusable electrochemical sensing platform, a simple, rapid, and selective biosensor for the determination of ultratrace terbium ions with a detection limit of 6.0 x 10(-11)M has been developed. The success in the present biosensor served as a significant step toward the development of monitoring ultratrace Tb(3+) in river water or seawater.