Background:
Acid-base derangements can be interpreted using the Stewart-Fencl approach, which includes calculation of the apparent strong ion difference (SID(app)), the effective SID (SID(eff)), and the strong ion gap (SIG). These calculations require the measurement of several variables. We hypothesized that the SID and SIG calculated by different analyzers would not be reproducible because of variability in the measured values.
Methods:
In this prospective observational study conducted in a biochemistry laboratory, we analyzed 179 routine blood samples from consecutive patients over a 3-mo period using two automated blood chemistry analyzers, the LX20 (Beckman) and the Modular (Roche). Measured and calculated parameters from the two analyzers were compared.
Results:
Although the correlation between measured values was satisfactory, there were large differences in the limits of agreement for calculated values (SID(app): 9.6 mEq/L, SID(eff): 6.4 mEq/L, and SIG: 11.7 mEq/L) and a weak correlation (SID(app): r(2) = 0.54 and SIG: r(2) = 0.12) between the analyzers.
Conclusions:
The results of the Stewart-Fencl approach for interpretation of acid-base status can vary according to the analyzer used. These differences may have important clinical and research implications..
More Related Videos
08:03A Tandem Liquid Chromatography–Mass Spectrometry-based Approach for Metabolite Analysis of Staphylococcus aureus
Published on: March 28, 2017
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...
Titration of Polyprotic Base with a Strong Acid
Titration of a Weak Acid with a Strong Base
Acid-Base Titration Curves
For a titration carried out for 25.00 mL of 0.100...
Relative Strengths of Conjugate Acid-Base Pairs