Related Experiment Video
Updated: Jun 20, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-acetonitrile nanodrops
Christopher J Hogan1, Juan Fernández de la Mora
1Department of Mechanical Engineering, Yale University, New Haven, CT, USA.
Abstract:
Ion evaporation is an essential step in the formation of charged ions from electrosprays, yet many aspects of the process are poorly understood. The ion evaporation kinetics of the 1-ethyl-3-methyl-imidazolium+ (EMI+) based ionic liquids (ILs) EMI-BF4, EMI-bis(perfluoroethylsulfonyl)imide, EMI-bis(trifluoromethylsulfonyl)imide and EMI-tris(trifluoromethylsulfonyl)methide (EMI-Methide) are studied by tandem ion mobility-mass spectrometry (IMS-MS) of IL nanodrop residues from positive and negative electrosprays of IL-acetonitrile solutions. Two-dimensional (2D) IMS-MS spectra are obtained using a differential mobility analyzer (DMA) coupled to a commercial quadrupole-time-of-flight mass spectrometer. Nanodrops of different charge states (z=1,2,...,10,...) are separated into distinct bands in 2D DMA-MS spectra, allowing for determination of both nanodrop size (radius) and charge. With the exception of negatively charged EMI-BF4, all clusters observed are charged below the Rayleigh limit of both the ILs and acetonitrile, showing that the charge loss mechanism is ion evaporation. Solvation energies, DeltaG, of evaporating ions from acetonitrile are inferred from radius and charge state data. With the exclusion of EMI-BF4 in negative mode (DeltaG>1.84 eV), all are in the 1.54-1.65 eV range, considerably lower than previously reported for tetra-alkyl ammonium salts in formamide. Measured size distributions of EMI-Methide nanodrops agree with those predicted by ion evaporation theory, though with narrower widths observed for doubly and singly charged nanodrops.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
16:40T-wave Ion Mobility-mass Spectrometry: Basic Experimental Procedures for Protein Complex Analysis
Published on: July 31, 2010
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrum: Interpretation