Related Experiment Video
Updated: Jun 20, 2026

Preparation of Poly(pentafluorophenyl acrylate) Functionalized SiO2 Beads for Protein Purification
Published on: November 19, 2018
Development of a polishing step using a hydrophobic interaction membrane adsorber with a PER.C6-derived recombinant
Michael Kuczewski1, Nathalie Fraud, Rene Faber
1PERCIVIA LLC, Cambridge, Massachusetts 02139, USA. mkuczewski@percivia.com
Abstract:
Membrane chromatography has already proven to be a powerful alternative to polishing columns in flow-through mode for contaminant removal. As flow-through utilization has expanded, membrane chromatography applications have included the capturing of large molecules, including proteins such as IgGs. Such bind-and-elute applications imply the demand for high binding capacity and larger membrane surface areas as compared to flow-through applications. Given these considerations, a new Sartobind Phenyl membrane adsorber was developed for large-scale purification of biomolecules based on hydrophobic interaction chromatography (HIC) principles. The new hydrophobic membrane adsorber combines the advantages of membrane chromatography-virtually no diffusion limitation and shorter processing time-with high binding capacity for proteins comparable to that of conventional HIC resins as well as excellent resolution. Results from these studies confirmed the capability of HIC membrane adsorber to purify therapeutic proteins with high dynamic binding capacities in the range of 20 mg-MAb/cm(3)-membrane and excellent impurity reduction. In addition the HIC phenyl membrane adsorber can operate at five- to ten-fold lower residence time when compared to column chromatography. A bind/elute purification step using the HIC membrane adsorber was developed for a recombinant monoclonal antibody produced using the PER.C6(R) cell line. Loading and elution conditions were optimized using statistical design of experiments. Scale-up is further discussed, and the performance of the membrane adsorber is compared to a traditional HIC resin used in column chromatography.
More Related Videos
10:33Isolation and Characterization Of Chimeric Human Fc-expressing Proteins Using Protein A Membrane Adsorbers And A Streamlined Workflow
Published on: January 8, 2014
10:50Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
Related Concept Videos
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Detergent Purification of Membrane Proteins