Aim:
To evaluate whether computer-aided detection (CAD) as a second reader using perspective filet view [three-dimensional (3D) filet] improves the performance of inexperienced readers at computed tomography colonography (CTC) compared with unassisted 3D filet and unassisted two-dimensional (2D) CTC.
Material And Methods:
Fifty symptomatic patients underwent CTC and same-day colonoscopy with segmental unblinding. Two inexperienced readers read the CTC studies on 3D filet and 2D several weeks apart. Four months later, readers re-read the cases only evaluating CAD marks using 3D filet. Suspicious CAD marks not previously described on 3D filet were recorded. Jackknife free-response receiver operating characteristic (JAFROC-1) analysis was used to compare the observers' performances in detecting lesions with 3D filet, 2D and 3D filet with CAD.
Results:
One hundred and three lesions > or =3mm were detected at colonoscopy with segmental unblinding. CAD alone had a sensitivity of 73% (75/103) at a mean false-positive rate per patient of 12.8 in supine and 11.4 in prone. For inexperienced readers sensitivities with 3D filet with CAD were 58% (60/103) and 48% (50/103) with an improvement of 14-16 percentage points (p<0.05) compared with 2D and of 10-11 percentage points (p<0.05) compared with 3D filet. For inexperienced readers, the false-positive rate was 25-41% and 71-200% higher with 3D filet with CAD compared with 3D filet and 2D, respectively. JAFROC-1 analysis showed no significant differences in per-lesion overall performance among reading modes (p=0.8).
Conclusion:
CAD applied as a second reader using 3D filet increased both sensitivity and the number of false positives by inexperienced readers compared with 3D filet and 2D, thus not improving overall performance, i.e., the ability to distinguish between lesions and non-lesions.
More Related Videos
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
06:28E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...