Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Optimized use of a 50 microm internal diameter secondary column in a comprehensive two-dimensional gas chromatography
Peter Quinto Tranchida1, Giorgia Purcaro, Lanfranco Conte
1Dipartimento Farmaco-chimico, Facoltà di Farmacia, Università di Messina, viale Annunziata, I-98168, Messina, Italy.
Abstract:
The focus of the present research is directed toward the development of a comprehensive two-dimensional gas chromatography (GC x GC) method, characterized by a greatly increased separation power, if compared with GC x GC approaches using classical column combinations. The analytical objective was achieved by using a 0.05 mm internal diameter (i.d.) capillary as second dimension, a split-flow approach reported in previous research (Tranchida, P. Q., Casilli, A., Dugo, P., Dugo, G. and Mondello, L. Anal. Chem. 2007, 79, 2266-2275), and a twin-oven GC x GC instrument. The column combination employed was an orthogonal one: an apolar 30 m x 0.25 mm i.d. column was linked, by means of a Y-union, to a flame ionization detector (FID)-connected high-resolution 1 m x 0.05 mm i.d. polar one and to a 0.20 m x 0.05 mm i.d. uncoated capillary segment; the latter was connected to a manually operated split valve, located on top of the second GC. As previously shown, the generation of optimum gas linear velocities in both dimensions can be attained by splitting gas flows at the outlet of the first dimension (Tranchida, P. Q., Casilli, A., Dugo, P., Dugo, G. and Mondello, L. Anal. Chem. 2007, 79, 2266-2275). An optimized GC x GC method was developed and exploited for the analysis of a complex petrochemical sample. The satisfactory results attained were directly compared with those observed using the same instrumentation, equipped with what can be defined as a classical GC x GC split-flow column set: the same primary column was connected to an FID-linked 1 m x 0.10 mm i.d. polar one and to a 0.30 m x 0.10 mm i.d. uncoated capillary. It will be herein illustrated that there is still room for significant progress in the GC x GC field.
More Related Videos
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Instrumentation
Principles Of Column Chromatography