Related Experiment Video
Updated: Jun 20, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Simultaneous enantioseparation of a basic active pharmaceutical ingredient compound and its neutral intermediate
Lili Zhou1, Vincent Antonucci, Mirlinda Biba
1Merck Research Laboratories, Merck and Co. Inc., Rahway, NJ 07065, USA. lili_zhou@merck.com
Abstract:
Simultaneous enantioseparation of a basic API compound, (R)-2-Amino-N-[2-[1,2-dihydro-1-(methylsulfonyl) spiro [3H-indole-3,4'-piperidin]-1'-yl]-2-oxo-1-[(phenylmethyloxy) ethyl]-2-methylpropanamide monomethanesulfonate (compound-A) and its neutral penultimate intermediate, (R)-2-BOC-Amino-N-[2-[1,2-dihydro-1-(methylsulfonyl) spiro [3H-indole-3,4'-piperidin]-1'-yl]-2-oxo-1-[(phenylmethyloxy) ethyl]-2-methylpropanamide monomethanesulfonate (compound-B) was investigated using reversed phase (RPLC) and normal phase liquid chromatography (NPLC). After an initial screening, a Sepapak-4 column, a new type of polysaccharide chiral stationary phase (CSP), was selected for further method development based on hits on separation selectivity for both compounds under RPLC and NPLC. After comparing the pros and cons, a method utilizing the Sepapak-4 chiral column (150 mm x 4.6 mm, 3 microm particle size) in RPLC mode was finally developed. Separations were performed in gradient elution mode starting at 50% A (10 mM, NH(4)COOH at pH 6.5)/50% B (50/50 EtOH/MeCN) to 25% A (10 mM, NH(4)COOH at pH 6.5)/75% B (50/50 EtOH/MeCN). The flow rate was 1.0 mL/min; the column temperature was 50 degrees C; the UV wavelength was 220nm and the mass spectrometric detection was APCI in the positive ionization mode. The reaction mixture sample was directly diluted in ethanol. Baseline enantioseparation were achieved for both compound-A and its intermediate simultaneously with resolution greater than 2.0. The method was validated in terms of injection precision, linearity, limit of detection (LOD), limit of quantitation (LOQ), accuracy, and ruggedness. The specificity of the method was further evaluated by spiking a mixture of enantiomers of compound-A and its intermediate into a reaction matrix containing all of the synthetic reagents. No matrix interference was observed across the elution windows of compound-A and its intermediate. Additionally, the peak purity of each enantiomer was evaluated by mass spectra, indicating the specificity of the method.
More Related Videos
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
09:57Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing (IEF) Method
Published on: June 14, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
Affinity Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...