Pre-analytical and analytical considerations for the determination of plasma renin activity
Julie Brossaud1, Jean-Benoît Corcuff
1Department of Nuclear Medicine, University Hospital and University of Bordeaux, France. julie.brossaud@u-bordeaux2.fr
Background:
Primary hyperaldosteronism diagnosis is helped by assaying renin concentrations either by immunodetection (active renin) or by enzymatic reaction followed by angiotensin I immunoassay (plasma renin activity). We investigated the impact of pre-analytical and analytical conditions on a PRA assay.
Methods:
PRA was assayed using a commercial kit. Firstly, a retrospective analysis of PRA results from 1yr was performed. Secondly, the impact of pre-analytical temperature conveyance/storage of samples was tested (4 and 25 degrees C). Thirdly, 2 durations of enzymatic reaction 1.5 and 18h were tested.
Results:
Retrospectively, 9.5% samples displayed elevated "blanks": calculating PRA with or without "blank" subtraction elicited a difference of >10% in 1/3 samples. There was a significant decrease of PRA values in samples left at 25 degrees C vs 4 degrees C (50% "blank" increase). Finally, the longer the enzymatic reaction (1.5 vs 18h), the higher the production of angiotensin I and the better the PRA assay sensitivity.
Conclusion:
We propose a 2 step procedure: a brief 1.5h enzymatic reaction time followed by a prolonged reaction (18h) only if PRA is <0.2ng mL(-1) h(-1). We would recommend performing "blank" samples for the brief enzymatic reaction time. Finally, conveyance/storage temperature does modify PRA results albeit in our hands this had little clinical impact.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...
Antihypertensive Drugs: Direct Renin Inhibitors
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...